Phone: +033 25005025

Email: info@alternativepower.in

Maximum Allowable Back Pressure 4
Temperature 125 Degree C (Class H)
Voltage 440 V
Number Of Cylinder 2
Bore & Stroke 95 x 110 mm
Lubricating Oil Consumption 0.1% Sec
Lubricating Oil Change Period 500 Hours
Exciter Type Brushless
Power 15 kVA
Engine Model G-15-II
Governor Type Mechanical
No. of Cylinders 2 / Inline
Speed 1500 RPM
Class of Governing G2
Battery Voltage 12 V
Battery Capacity 88 Ah
Frequency 50 Hz
Fuel Tank Capacity 50 Liter
Engine Rating or Max. Power at Rated RPM 15.9 kW (21.6) BHP
Recommended Fuel HSD
Recommended Lubricating Oil Grade 1540 Greaves Maxtherm API CI4
Water Pump Type Engine Mounted
Air Cleaner Type Dry
Lubricating Oil Filter Type Spin on Type
Radiator System Capacity 7.5 Liter
Current 20.8 A
Genset Model GPWII-PII-15X
Displacement 1.56 Liter
Compression Ratio 17 Ratio 5
Over Speed Trip 1650 RPM
Insulation Class H
Weight 660 kg
Phase 3 Phase
Dimension 1420 x 930 x 1242 mm
Brand Greaves Power
Engine Type Natural Aspirated
Lubricating Oil Filter Quantity Single
Engine with direct injection, water-cooled engine, 2 cylinder, in-line, 4 stroke,rated at 1500RPM, conforming to ISO 3046 / BS 5514 has the following specifications:
Mechanical FIP
Mechanical governor / Electronic Governor (Optional)
Exhaust manifold, stainless steel exhaust flexible connection
Radiator Cooled
Filters – fuel, lube oil
Dry type replaceable paper element air cleaner
Flywheel housing and flywheel to suit single bearing alternator
Starting motor – Electric, battery charging alternator
First fill lube oil and coolant

Alternator:
Meccalte / (Optional -Stamford/ Crompton Greaves /equivalent)
Brushless alternator
Self-excited, self-regulated
Class ‘H’ insulation limited to temperature rise
Salient pole revolving field
Single bearing
Automatic voltage regulator.

Acoustic Enclosure:
Engine alternator assembly mounted on AVM with Silencer and S.S exhaust bellow suitably optimized to meet stringent sound emission standards as laid down by MOEF / CPCB
Base rail with draw-out type fuel tank is provided with a drain plug, air Vent inlet and outlet connections, level indicator, manhole etc
Sub-base fuel tank with 17 hour’s capacity at 75% Load
Dry, batteries with connecting leads and terminals
90% gloss RAL9003 white pure polyester powder coated, base in black colour

Control panel:
RAL 9003 white Powder coated control panel manufactured with CRCA sheet,

Control Panel Having Following Features:
MCB of suitable rating with short circuit protection
Controller which displays voltage, current, KW, PF, Frequency, KWh.
Indicating lamps for “Load On” and “Set Running”
Current transformers of suitable ratings
Copper cables of suitable capacity with incoming and Outgoing terminations
Control fuses duly wired and ferruled

Power cables:
Uninyvin copper conductor cables between Alternator & Control panel inside the canopy.

Literature:
Operation Manual
General maintenance & installation Guideline
Foundation Drawing
Parts manual

Fuel consumption –

LPH at % load:
100% 3.5
75% 2.7
50% 2.0
25% 1.35

Alternator Specifications:
Current @ 0.8PF (Amps) 65.2/20.8
Type 4 Pole , Rotating field
Leads: Quantity , type 6, fixed 12, re connectable (Optional)
Voltage Regulator: Solid State
Bearing: Quantity , type 1,Sealed
Coupling Flexible disc, Close coupled
Voltage regulation : No load to full load 2 Phase sensing,±1%
One step load acceptance 100% of rating
Unbalance load capability 25% of rated current